EPAR TRI 1 Channel Mode - DMX Values and Functions
Channel Value Function
1 COLOR MACROS
0 OFF
1 - 7 BASTARD AMBER
8 - 15 MEDIUM AMBER
16 - 23 PALE AMBER GOLD
24 - 31 GALLO GOLD
32 - 39 GOLDEN AMBER
40 - 47 LIGHT RED
48 - 55 MEDIUM RED
56 - 63 MEDIUM PINK
64 - 71 BROADWAY PINK
72 - 79 FOLLIES PINK
80 - 87 LIGHT LAVENDER
88 - 95 SPECIAL LAVENDER
96 - 103 LAVENDER
104 - 111 INDIGO
112 - 119 HEMSLEY BLUE
120 - 127 TIPTON BLUE
128 - 135 LIGHT STEEL BLUE
136 - 143 LIGHT SKY BLUE
144 - 151 SKY BLUE
152 - 159 BRILLIANT BLUE
160 - 167 LIGHT GREEN BLUE
168 - 175 BRIGHT BLUE
176 - 183 PRIMARY BLUE
184 - 191 CONGO BLUE
192 - 199 PALE YELLOW GREEN
200 - 207 MOSS GREEN
208 - 215 PRIMARY GREEN
216 - 223 DOUBLE CTB
224 - 231 FULL CTB
232 - 239 HALF CTB
240 - 247 DARK BLUE
248 - 255 WHITE
Master-Slave Operation:
This function will allows you to link units together to run in a Master-Slave
mode. In Master-Slave operation one unit will act as the controlling unit
and the others will react to the controlling units built-in programs. Any
unit can act as a Master or as a Slave however, only one unit can be pro-
grammed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit.
Use standard XLR data cables to link your units together. Remem-
ber that the Male XLR connector is the input and the Female XLR
connector is the ouput. The first unit in the chain (master) will use
the female XLR connector only. The last unit in the chain will use the
male XLR connector only.
2. Set the “Master” unit to your desired mode or operation.
3. For the “Slave” unit(s), set the display to any DMX channel mode.
Example: Set the unit to 4 channel mode, the display should read
“3000” or any variables, i.e “3001”, “3002 etc..
4. Connect the “Slave” unit or units and they will automatically start to
follow the “Master.”
EPAR TRI Master-Slave Configuration
EPAR TRI Operating Instructions
2. There are 5 dimmer curve settings to choose from. Please see the
Dimmer Curve Diagram Chart on page 16 to see the settings and
their respective beginning and ending fade times.
Power Consumption Adjustment:
1. Plug the fixture in and press the MODE button until “PXXX” is dis-
played. “XXX” representing a number between 001-003.
2. “001” is the lowest power consumption, and “003” is highest power
consumption. To change the power consumption press the UP or
DOWN buttons for at least 15 seconds. See page 17 for a power
consumption setting chart.
NOTE: The power consumption setting will have a tiny effect on the out-
put intensity.